Get Node Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Get Node Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the node configuration.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 97h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand = 07h |
| 5 | bladeid, 1 based |
| 6 | Node configuration parameters. For details, see Table 1. |
| 7 | Read offset, starting from 0. |
| 8 | Length: read length. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | End of List, indicating whether the current data is complete. Long data may need to be read multiple times. This field is used to check whether data is completely read. [7:1]: reserved [0]: End of list 0=last data 1=middle data |
| 6:N | Indicates the data. The returned data may be less than or equal to the read length. |
Reference
Table 1 Node Configuration Parameter
| Parameter | Parameter Data | No. (Decimal) | |
|---|---|---|---|
| Enable NC collect | read-write | data1:1- 1:enable 0:disable | 1 |
Command Example
Obtain the node configuration.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN