Get Multi-host Parameter
更新时间: 2026/08/06
在Gitcode上查看源码

Get Multi-host Parameter

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to query the partition state (for 8P servers or later).

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD97h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 02h
5Multi-host Parameter 1 based
See Table 1.
6Block_selector
7Read Offset
Indicates the offset of the read data. The value starts from 0.
8Length
Read length.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5End of List
indicates whether the data reading is complete, Long data may need to be read multiple times. This field is used to check whether data is completely read.
[7:1]: reserved
[0]: cascading flag
0: last data
1: middle data
6:NData
The returned data may be less than or equal to the read length.

Reference

Table 1 Table partitioning description

Parameter#Description#(Decimal)
Moderead-onlydata1: Multi-host Mode;
0h: independent mode, physical partition mode
1h-multi-host 8P mode
1

Command Example

Query the partition state.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN