Function Description

Set an IP address for the VLANIF interface of the XCU board.

Privilege

Command Information

Request Information

ByteData Field
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 0ah
5:8IpAddr
9:12Netmask
13:16VlanID

Response Information

ByteData Field
1Completion Code
(00h)Succeed
(C9h)Invalid VlanID
(CCh)Invalid IpAddr or Netmask
(CEh)Command response could not be provided.
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.