Get Port Mapping
更新时间: 2026/08/06
在Gitcode上查看源码Get Port Mapping
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the port mapping.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 95h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command =08h |
| 5 | Request frame number |
| 6 | Slot number of the server blade. If the value is 0xff, the information about all ports is returned. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code (00h)Succeed (C9h)Invalid parameter for unsupported component (CCh)Invalid data field for unsupported component (CEh)Command response could not be provided. |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Total number of IPMI frames |
| 6 | Response frame number |
| 7 | Total number of ports for sending the message |
| 8:36 | 8-32: port name 33: port status, 0: down, 1: up 34: port type 0:GE 1:10GE 2:40GE 3:100GE 35: port rate 0:10M 1:100M 2:1000M 3:10G 4:40G 5:100G 36: indicates the slot number of a server blade. The default value is 0xff for a panel port. |
| 37:N | Ports |
Command Example
Obtain the port mapping.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN