代码仓
中
Get Port Mapping
更新时间: 2026/08/06
在AtomGit上查看源码

Get Port Mapping ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Obtain the port mapping.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD95h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command =08h
5Request frame number
6Slot number of the server blade. If the value is 0xff, the information about all ports is returned.

Response Information ​

ByteData Field
1Completion Code
(00h)Succeed
(C9h)Invalid parameter for unsupported component
(CCh)Invalid data field for unsupported component
(CEh)Command response could not be provided.
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Total number of IPMI frames
6Response frame number
7Total number of ports for sending the message
8:368-32: port name
33: port status, 0: down, 1: up
34: port type
0:GE
1:10GE
2:40GE
3:100GE
35: port rate
0:10M
1:100M
2:1000M
3:10G
4:40G
5:100G
36: indicates the slot number of a server blade. The default value is 0xff for a panel port.
37:NPorts

Command Example ​

Obtain the port mapping. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​