Get Shelf Device Power State
更新时间: 2026/08/06
在Gitcode上查看源码Get Shelf Device Power State
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Querying the Power-On and Power-Off Status of a Shelf or Node Through the Management Module
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=69h |
| 5 | Type (0: chassis; 1: compute node; 2: storage node) |
| 6 | Slot id |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Power state. 0: power-off; 1: power-on. |
Command Example
Query the power status of the compute node in slot 0.
Request:
bash
ipmitool raw 0x30 0x94 0xdb 0x07 0x00 0x69 0x01 0x0Response:
text
0x00 0xdb 0x07 0x00 0x02f