代码仓
中
Get Shelf Device Power State
更新时间: 2026/08/06
在AtomGit上查看源码

Get Shelf Device Power State ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Querying the Power-On and Power-Off Status of a Shelf or Node Through the Management Module

Privilege ​

BasicSetting

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=69h
5Type (0: chassis; 1: compute node; 2: storage node)
6Slot id

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Power state. 0: power-off; 1: power-on.

Command Example ​

Query the power status of the compute node in slot 0. ​

Request:

bash
ipmitool raw 0x30 0x94 0xdb 0x07 0x00 0x69 0x01 0x0

Response:

text
0x00 0xdb 0x07 0x00 0x02f

Back to Index ​