Shelf Device Power State Control
更新时间: 2026/08/06
在Gitcode上查看源码

Shelf Device Power State Control

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Controlling the Power-On and Power-Off of a Shelf or Node Through the Management Module

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=68h
5Type (0: chassis; 1: compute node; 2: storage node)
6Slot id
7Operate (0: power-off; 1: power-on; 2: forcible power-off)

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Power off the compute node in slot 0.

Request:

bash
ipmitool raw 0x30 0x94 0xdb 0x07 0x00 0x68 0x01 0x0 0x0

Response:

text
0x00 0xdb 0x07 0x00

Back to Index