Shelf Device Power State Control
更新时间: 2026/08/06
在Gitcode上查看源码Shelf Device Power State Control
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Controlling the Power-On and Power-Off of a Shelf or Node Through the Management Module
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=68h |
| 5 | Type (0: chassis; 1: compute node; 2: storage node) |
| 6 | Slot id |
| 7 | Operate (0: power-off; 1: power-on; 2: forcible power-off) |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Power off the compute node in slot 0.
Request:
bash
ipmitool raw 0x30 0x94 0xdb 0x07 0x00 0x68 0x01 0x0 0x0Response:
text
0x00 0xdb 0x07 0x00