Get Stateless Compute Parameter
更新时间: 2026/08/06
在Gitcode上查看源码

Get Stateless Compute Parameter

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtains stateless computing parameters.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 22h
5Parameter selector, starting from 1. For details, see Table 1.
6Set Selector. Selects a given set of parameters under a given Parameter selector value. 00h if parameter doesn't use a Set Selector
7Indicates the read offset. The value starts from 0.
8Length: read length.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5End of List, indicating whether the current data is complete. Long data may need to be read multiple times. This field is used to check whether data is completely read.
[7:1]reserved
[0]: cascading flag
0: last data
1: middle data
6:NIndicates the data. The returned data may be less than or equal to the read length.

Command Example

Obtain stateless computing parameters.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index