Get KVM Parameter
更新时间: 2026/08/06
在Gitcode上查看源码

Get KVM Parameter

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to obtain KVM parameters.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command: 20h
5Parameter selector, starting from 1. For details, see Table 1.
6Indicates the read offset. The value starts from 0.
7Length: read length.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5End of list, indicating whether the data reading is complete.
Long data may need to be read multiple times. This field is used to check whether data is completely read.
[7:1]: reserved
[0]: cascading flag
0: last data
1: middle data
6:NIndicates the data. The returned data may be less than or equal to the read length.

Command Example

Read the old and new algorithms supported by KVM.

Request:

bash
ipmitool raw 0x30 0x94 0xDB 0x07 0x00 0x20 0x01 0x00 0xff

Response:

text
 db 07 00 00 03

Back to Index