Set Blade Global Configuration ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Set global node parameters.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 1fh
5Bladeid 1 based
6Blade Configuration Parameter
7[7:1]: reserved
[0]: cascading flag
0: last frame of data
1: middle data
8Offset
Offset of the written data, starting from 0.
Write data in sequence when they are written as multiple frames.
9Length
Length of the written data
10:NWritten data

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set global parameters for a node. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​