Set Blade Global Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Set Blade Global Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set global node parameters.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 1fh |
| 5 | Bladeid 1 based |
| 6 | Blade Configuration Parameter |
| 7 | [7:1]: reserved [0]: cascading flag 0: last frame of data 1: middle data |
| 8 | Offset Offset of the written data, starting from 0. Write data in sequence when they are written as multiple frames. |
| 9 | Length Length of the written data |
| 10:N | Written data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set global parameters for a node.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN