Set Blade MEZZ Card Present ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

This command is used to send the in-position information about the mezzanine card on the front board to the switch board (applicable only to the OSCA server switch board).

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 1Eh
5:Ndata1-slot total: number of slots of the front boards where the mezzanine cards are installed
data2-slot id, 1 based
data3-physical MEZZ present mask, MEZZ1 corresponds to bit0.
......
data(N-1)-slot id, 1 based
dataN-physical MEZZ present mask, MEZZ1 corresponds to bit0.

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Send the installation status of the mezzanine card on the front board to the switch board. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN