Set Blade Info Parameters
更新时间: 2026/08/06
在Gitcode上查看源码Set Blade Info Parameters
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set node parameters.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=1Dh |
| 5 | Parameter selector. For details, see Table 1. |
| 6:N | Configuration parameter data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code 80h=parameter not supported. 81h=attempt to set the 'set in progress' value (in parameter #0) when not in the 'set complete' state. (This completion code provides a way torecognize that another party has already 'claimed' the parameters) 82h=attempt to write read-only parameter |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Reference
Table 1 Blade Info Parameters Table
| Parameter | # | Parameter Data | #(Decimal) |
|---|---|---|---|
| Present | rw | data1-slot maximum: maximum number of front board slots supported by the chassis data2: 5-blade present. Each bit indicates the presence status of a board in a slot. 0-absent, 1-present, LSB first | 1 |
| Board ID | rw | data1-slot maximum: maximum number of front board slots supported by the chassis data2: 3-blade1 board ID. FFFFh indicates that the board is invalid (the board is not in position or the board ID fails to be obtained). LSB first ... dataM:M+1-bladeN board id | 2 |
| BMC Hard Reset | w | data1-slot id, slot ID, 0 base Performs a hard reset on the BMC of a node in a specified slot. | 3 |
Command Example
Set node information parameters.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN