Get Port Info Parameters
更新时间: 2026/08/06
在Gitcode上查看源码

Get Port Info Parameters

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtains the port information.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 1 Ah
5Parameter selector
6Set Selector. Selects a given set of parameters under a given Parameter selector value. 00h if parameter doesn't use a Set Selector
7:10Block Selector (00h if parameter does not require a block number), LSB first
11Sub Block Selector (00h if parameter does not require a block number)
12Option Selector (00h if parameter does not require a block number)

Response Information

ByteData Field
1Completion Code
Generic codes, plus following command-specific completion code(s):
80h=parameter not supported
83h=no more data
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:NConfiguration parameter data

Command Example

Obtain port information.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN