Set Device GUID ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

This command is used to set the device GUID (for OSCA servers only).

Privilege ​

UserMgnt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 11h
5:20GUID

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set the device GUID. ​

Request:

bash
ipmicmd -k "0f 00 30 94 DB 07 00 11 AB 8C FF C2 2C 2E 11 EA B1 E2 20 20 12 21 17 50" smi 0

Response:

text
0f 31 00 94 00 db 07 00