Set Device GUID
更新时间: 2026/08/06
在Gitcode上查看源码

Set Device GUID

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to set the device GUID (for OSCA servers only).

Privilege

UserMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 11h
5:20GUID

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the device GUID.

Request:

bash
ipmicmd -k "0f 00 30 94 DB 07 00 11 AB 8C FF C2 2C 2E 11 EA B1 E2 20 20 12 21 17 50" smi 0

Response:

text
0f 31 00 94 00 db 07 00

Back to Index