Set Device GUID
更新时间: 2026/08/06
在Gitcode上查看源码Set Device GUID
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This command is used to set the device GUID (for OSCA servers only).
Privilege
UserMgnt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand = 11h |
| 5:20 | GUID |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the device GUID.
Request:
bash
ipmicmd -k "0f 00 30 94 DB 07 00 11 AB 8C FF C2 2C 2E 11 EA B1 E2 20 20 12 21 17 50" smi 0Response:
text
0f 31 00 94 00 db 07 00