Set Power Unit Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Set Power Unit Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set power unit parameters.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=10h |
| 5 | Power Unit Selector, 1 based |
| 6 | Power unit configuration. For details, see Table 1. |
| 7 | [7:1]-reserved [0]: cascading flag 0: last data 1: middle data |
| 8 | offset: offset of the written data, starting from 0. When a large amount of data needs to be written for multiple times, the data must be written in sequence from the beginning to the end. |
| 9 | Length: indicates the length of the written data. |
| 10:N | Written data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the power unit configuration.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN