Get Power Unit Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Get Power Unit Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the power unit configuration.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=0Fh |
| 5 | Power Unit Selector, 1 based |
| 6 | Power unit configuration. For details, see Power Unit Configuration. |
| 7 | Indicates the read offset. The value starts from 0. |
| 8 | Length: read length |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | End of list, indicating whether the data reading is complete. Long data may need to be read multiple times. This field is used to check whether data is completely read. [7:1]-reserved [0]: cascading flag 0: last data 1: middle data |
| 6:N | Indicates the data. The returned data may be less than or equal to the read length. |
Reference
Table 1 Power Unit Configuration
| Parameter | - | Parameter Data | #(Decimal) |
|---|---|---|---|
| Switch Status | rw | data1:1-Get/Set Algorithm Enabling Status 0: automatic. The user cannot power off the device. 1: manual. Users can power off the device. | 1 |
| Rest Status | rw | data1:1-Get/Set Sleep This parameter is valid only in automatic mode. 0: Disable hibernation. 1: Enable hibernation. | 2 |
Command Example
Obtain the power unit configuration.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN