Get Power Unit Configuration
更新时间: 2026/08/06
在Gitcode上查看源码

Get Power Unit Configuration

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtain the power unit configuration.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=0Fh
5Power Unit Selector, 1 based
6Power unit configuration. For details, see Power Unit Configuration.
7Indicates the read offset. The value starts from 0.
8Length: read length

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5End of list, indicating whether the data reading is complete. Long data may need to be read multiple times. This field is used to check whether data is completely read.
[7:1]-reserved
[0]: cascading flag
0: last data
1: middle data
6:NIndicates the data. The returned data may be less than or equal to the read length.

Reference

Table 1 Power Unit Configuration

Parameter-Parameter Data#(Decimal)
Switch
Status
rwdata1:1-Get/Set
Algorithm Enabling Status
0: automatic. The user cannot power off the device.
1: manual. Users can power off the device.
1
Rest
Status
rwdata1:1-Get/Set
Sleep
This parameter is valid only in automatic mode.
0: Disable hibernation.
1: Enable hibernation.
2

Command Example

Obtain the power unit configuration.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index