Basic Information
Function Description
This command is used to obtain the SOL destination name (for OSCA servers only).
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 94h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=0Eh |
| 5 | Dest Selector |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | SOL Type |
| 6:21 | SOL destination name, set to 00h if shorter than 16 bytes. |
Command Example
Obtain the SOL destination name.
Request:
bash
ipmicmd -k "0f 00 30 94 db 07 00 0e 01" smi 0Response:
text
0f 31 00 94 00 db 07 00 00 53 59 53 20 43 4f 4d 00 00 00 00 00 00 00 00 00