Set FC portconnect
更新时间: 2026/08/06
在Gitcode上查看源码

Set FC portconnect

Change History

openUBMC VersionRevision DateDescription
25.062026/08/06Initial draft: add command details

Basic Information

Function Description

Set up a Fibre Channel port connection.

Privilege

Command Information

Request Information

ByteData Field
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 07h
5Indicates the FC port ID. If the value is 0xff, all ports are returned.
6Fibre Channel Port Connection Configuration
0h=left
1h=right

Response Information

ByteData Field
1Completion Code
(00h)Succeed
(C9h)Invalid parameter for unsupported component
(CCh)Invalid data field for unsupported component
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the FC port connection.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index