代码仓
中
Set Chassis Number
更新时间: 2026/08/06
在AtomGit上查看源码

Set Chassis Number ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

This command is used to set the subrack number (applicable only to OSCA servers).

Privilege ​

BasicSetting

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 07h
5:8Chassis Number

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set the chassis number. ​

Request:

bash
ipmicmd -k "0f 00 30 94 db 07 00 07 01 02 03 04" smi 0

Response:

text
0f 31 00 94 00 db 07 00

Back to Index ​