Function Description

This command is used to set the subrack number (applicable only to OSCA servers).

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 07h
5:8Chassis Number

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the chassis number.

Request:

bash
ipmicmd -k "0f 00 30 94 db 07 00 07 01 02 03 04" smi 0

Response:

text
0f 31 00 94 00 db 07 00