代码仓
中
Get FC portconnect
更新时间: 2026/08/06
在AtomGit上查看源码

Get FC portconnect ​

Change History ​

openUBMC VersionRevision DateDescription
25.062026/08/06Initial draft: add command details

Basic Information ​

Function Description ​

Obtain the Fibre Channel port connection.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 06h
5FC port number. If the value is 0xff, all ports are returned.

Response Information ​

ByteData Field
1Completion Code
(00h)Succeed
(C9h)Invalid parameter for unsupported component
(CCh)Invalid data field for unsupported component
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Fibre Channel port number. The value ranges from 1 to 8. The value 0xff indicates that all ports are valid, and the value 0 indicates that all ports are invalid.
6Fibre Channel port connection configuration. Each bit indicates a port. LSB first
0h=left
1h=right
[7] Port 8
[6] Port 7
......
[0] Port 1

Interconnected Component ​

[BIOS][Equipment][SMM]

Command Example ​

Obtain the Fibre Channel port connection. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​