代码仓
中
Get Switch Info Parameters Command
更新时间: 2026/08/06
在AtomGit上查看源码

Get Switch Info Parameters Command ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Obtain component information.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD94h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 02h
5Parameter selector
6Set Selector
Selects a given set of parameters under a given Parameter selector value.
00h if parameter doesn't use a Set Selector
7Block Selector (00h if parameter does not require a block number,16Bytes Per block)
8Sub Block Selector (00h if parameter does not require a block number,16Bytes Per block)

Response Information ​

ByteData Field
1Completion Code
Generic codes, plus following command-specific completion code(s):
80h=parameter not supported.
83h=no more data
84h=not support information inquiry, because the DAC cable inserted.
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:NConfiguration parameter data

Command Example ​

Obtain component information. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​