Get Asset Management Configuration
更新时间: 2026/08/06
在Gitcode上查看源码

Get Asset Management Configuration

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Query asset management configuration information.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=8Dh
5Parameter selector. For details, see Table 1.
6:7Reserved. The default value is 00h.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:NResponse data. For details, see Table 1.

Reference

Table 1 Asset configuration parameters

# (Byte5)ParameterDataRead/Write type
01hEnabling status of supply chain configuration checkdata1: enabling status of supply chain configuration check
00h The supply chain configuration check function is disabled.
01h The supply chain configuration check function has been enabled.
read-write
02hSet Trustworthy Supply Chain Baseline Configurationdata1 - Sets the trusted supply chain baseline configuration.
01h Update the trustworthy supply chain baseline configuration.
writeonly
03hQuerying the Trustworthy Supply Chain Reference Value Generation ResultTrustworthy supply chain baseline generation result:
00h: not generated
01h Generating
02h generated successfully.
03h generation failed.
CAUTION: The query result is 00h by default after the generation action is not performed and the BMC is restarted, indicating that the generation is not started.
read-only

Command Example

Obtain the enabling status of the supply chain configuration check function.

Request:

bash
ipmitool raw 0x30 0x93 0xdb 0x07 0x00 0x8D 0x01 0x00 0x00

Response:

text
db 07 00 01

Back to Index