Get Asset Management Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Get Asset Management Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Query asset management configuration information.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=8Dh |
| 5 | Parameter selector. For details, see Table 1. |
| 6:7 | Reserved. The default value is 00h. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:N | Response data. For details, see Table 1. |
Reference
Table 1 Asset configuration parameters
| # (Byte5) | Parameter | Data | Read/Write type |
|---|---|---|---|
| 01h | Enabling status of supply chain configuration check | data1: enabling status of supply chain configuration check 00h The supply chain configuration check function is disabled. 01h The supply chain configuration check function has been enabled. | read-write |
| 02h | Set Trustworthy Supply Chain Baseline Configuration | data1 - Sets the trusted supply chain baseline configuration. 01h Update the trustworthy supply chain baseline configuration. | writeonly |
| 03h | Querying the Trustworthy Supply Chain Reference Value Generation Result | Trustworthy supply chain baseline generation result: 00h: not generated 01h Generating 02h generated successfully. 03h generation failed. CAUTION: The query result is 00h by default after the generation action is not performed and the BMC is restarted, indicating that the generation is not started. | read-only |
Command Example
Obtain the enabling status of the supply chain configuration check function.
Request:
bash
ipmitool raw 0x30 0x93 0xdb 0x07 0x00 0x8D 0x01 0x00 0x00Response:
text
db 07 00 01