代码仓
中
Get Trusted Computing Configuration
更新时间: 2026/08/06
在AtomGit上查看源码

Get Trusted Computing Configuration ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Queries the trusted computing configuration. Currently, only specific models and versions support this command.

Privilege ​

ReadOnly

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=88h
5Function. For details about the function ID, see Table 1.
6Reserved
7Reserved

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Length of the queried configuration information (N)
6:NQuery result. For details, see Table 2.

Table 1 Function description

Function IDFunction
01hBasic Secure Running Capabilities (Query Only)
02hEnabling status of basic secure running capabilities

Table 2 Function and status mapping

Function IDStatus codes and descriptions
01h00h: The basic secure running capability is not supported.
01h: Basic secure running capabilities are supported.
02h00h: The basic secure running capability is disabled.
01h: The basic secure running capability is enabled.
CAUTION: After the basic secure running capability is enabled, restart the BMC for the setting to take effect.

Command Example ​

Query whether the basic secure running capability is supported. ​

Request:

bash
ipmitool raw 0x30 0x93 0xdb 0x07 0x00 0x88 0x01 0x00 0x00

Response:

text
db 07 00 01 01

Back to Index ​