Get NTP Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Get NTP Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Query the NTP configuration.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Subcommand, subcommand=82h |
| 5 | Selector. For details, see Table 1. |
| 6 | length: indicates the length of the requested data. |
| 7:N | data: request data. If the data length is 0, this parameter can be left empty. For details, see Table 1. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | length: valid length of the response data |
| 6:N | data: response data. For details, see Table 1. |
Command Example
Obtain the NTP enabling status.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 82 00" smi 0Response:
text