Get authentication algorithm
更新时间: 2026/08/06
在Gitcode上查看源码Get authentication algorithm
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Querying the SNMPv3 Authentication Algorithm of a User
Privilege
UserMgnt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command=80h |
| 5 | User ID |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | SNMPAuthProtocol 00h=MD5 01h=SHA 02h=SHA1 03h=SHA256 04h=SHA384 05h=SHA512 |
Command Example
Obtain component customization information.
Request:
bash
ipmitool raw 0x30 0x93 0xDB 0x07 0x00 0x80 0x03Response:
text
00 03