Get Account Interface
更新时间: 2026/08/06
在Gitcode上查看源码

Get Account Interface

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This interface is used to query users.

Privilege

UserMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=79h
5[7]:[6]: reserved
[5]:[0]: Userid

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5bit0-Web: 0 disabled; 1 enabled
bit1-SNMP: 0 disabled; 1 enabled
bit2-IPMI: 0 disabled; 1 enabled
bit3-SSH: 0 disabled; 1 enabled
bit4-SFTP: 0 disabled; 1 enabled
bit6-Local: 0 disabled; 1 enabled
bit7-Redfish: 0 disabled; 1 enabled

Command Example

Query the interface of user 3.

Request:

bash
ipmitool raw 0x30 0x93 0xDB 0x07 0x00 0x79 0x03

Response:

text
 db 07 00 df

Back to Index