Ipmi Check Upgrade Channel Health
更新时间: 2026/08/06
在Gitcode上查看源码

Ipmi Check Upgrade Channel Health

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Before the upgrade, check whether the JTAG and I2C channels are healthy. The upgrade is supported.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=78h
5Query type:
0: Check the health status of the CPLD upgrade channel and obtain the result.
1: Check the health status of the 5902L upgrade channel.
2: Obtain the health status of the 5902L upgrade channel. (Note: The health status of the 5902L upgrade channel is directly obtained without check, and the returned value is meaningless.)
6device_type: checking whether the CPLD upgrade channel is added
7Device_num: checks whether the CPLD upgrade channel is added.
8component_type: checks whether the CPLD upgrade channel is added.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Result:
0: The channel is healthy or the command is sent successfully.
1: The channel does not support upgrade or the command fails to be sent.

Command Example

Obtain the JTAG health status of the CPLD upgrade channel.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 78 00 10 00 05" smi 0

Response:

text
db 07 00 00

Back to Index