Get SNMP Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Get SNMP Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain SNMP settings.
Privilege
UserMgmt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=75h |
| 5 | SNMP parameter. For details, see SNMP Parameter. |
| 6 | Block Selector (00h if parameter does not require a block number) |
| 7 | Sub Block Selector (00h if parameter does not require a sub block number) |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Message Len: N. The actually returned data may be less than or equal to Read length. |
| 6:5+N | Message Info |
SNMP parameters
| Parameter | Parameter Data (hexadecimal) | Block Selector | Block Selector Data (hexadecimal) | Sub Block Selector | Sub Block Selector (hexadecimal) | Data |
|---|---|---|---|---|---|---|
| SNMP | 1 | Community name | 1 | Read-only community name. | 1 | A character string of 1 to 32 bytes |
| - | R/W community | 2 | A character string of 1 to 32 bytes | |||
| Long Password Enable | 2 | - | - | 1 byte 0: disable; 1: enable | ||
| Trap (reserved) | 2 |
Command Example
Query the SNMP read-only community name.
Request:
bash
Ipmitool raw 0x30 0x93 0xdb 0x07 0x00 0x75 0x01 0x01 0x01Response:
text
db 07 00 14 72 6f 41 64 6d 69 6e 69 73 74 72 61 74 6f 72 40 39 30 30 30