Set SNMP Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Set SNMP Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set the SNMP configuration.
Privilege
UserMgmt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=74h |
| 5 | SNMP parameter. For details, see SNMP Parameter. |
| 6 | Block Selector (00h if parameter does not require a block number) |
| 7 | Sub Block Selector (00h if parameter does not require a sub block number) |
| 10 | Length: write length |
| 11:10+N | Written data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Configure SNMP and enable the long password function.
Request:
bash
Ipmitool raw 0x30 0x93 0xdb 0x07 0x00 0x74 0x01 0x02 0x00 0x00 0x01Response:
text
db 07 00 00