Get Sensor Over Temp Power Off Threshold
更新时间: 2026/08/06
在Gitcode上查看源码Get Sensor Over Temp Power Off Threshold
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the overtemperature power-off threshold of a sensor.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=6Eh |
| 5 | Reserved. Set this parameter to 0. |
| 6 | Sensor Index |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Whether to enable the function of triggering OS power-off due to sensor overtemperature 0: The function is disabled. (When the function is disabled, the sensor threshold is not returned.) 1: The quick policy is enabled. |
| 6-7 | Indicates the overtemperature power-off threshold of the current sensor. The least significant byte is in the front. |
Command Example
Obtain the overtemperature power-off threshold of the sensor.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 6e 00 01" smi 0Response:
text
0f 31 00 93 db 07 00 01 32 00