Set Sensor Over Temp Power Off Threshold (Deprecated)
更新时间: 2026/08/06
在Gitcode上查看源码

Set Sensor Over Temp Power Off Threshold (Deprecated)

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Sets the overtemperature power-off threshold for a sensor.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=6Dh
5Reserved. Set this parameter to 0.
6Whether to enable the function of triggering OS power-off due to sensor overtemperature
0: The function is disabled. (When the function is disabled, you do not need to enter the sensor threshold.)
1: The function is enabled.
7Sensor index:
1: air intake vent temperature sensor
Other values are reserved.
8-9Sensor overtemperature power-off threshold. The least significant byte is in the front.
Temperature sensor at the air intake vent: The preset value cannot be lower than 50°C.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. .

Command Example

Set the overtemperature power-off threshold for a sensor.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 6d 00 01 01 32 00" smi 0

Response:

text
0f 31 00 93 db 07 00