Set Product CCDB Info
更新时间: 2026/08/06
在Gitcode上查看源码Set Product CCDB Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Writes product CCDB data.
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=6Bh |
| 5 | Operate=0x30 |
| 6 | type: 1: Fast write/write to the flash memory. 0: The slow write/write memory is updated to the flash memory every 24 hours. |
| 7:14 | Version, little endian, 8 bytes in total |
| 15 | CCDB data length. The value is 1:232. |
| 16:n | CCDB data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | state 1: Successful. 4: The version number is incorrect. 5: The CCDB data length is incorrect. 6: CCDB initialization is not complete. 8: error |
Command Example
Write the product CCDB data.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 6b 30 01 01 17 34 19 20 01 22 22 01 01" smi 0Response:
text
0f 31 00 93 00 01