Deregister Product Arbitration Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This command is used to preempt data.
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=6Bh |
| 5 | Operate=0x2E |
| 6:13 | Version, little endian, 8 bytes in total |
| 14:21 | Key data (8 bytes) |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | state 1: Successful. 3: The internal status is incorrect, not initialized, or not registered. 4: The version number is incorrect. 7: The key is not registered. |
Command Example
Display product preemption data.
Request:
ipmicmd -k "0f 00 30 93 db 07 00 6b 2e 01 17 34 19 20 01 22 22 01 17 34 19 20 01 22 20" smi 0Response:
0f 31 00 93 00 01 01 17 34 19 20 01 22 22 01 17 34 19 20 01
22 20 ff ff ff ff ff ff ff ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
ff ff