Set Account Interface
更新时间: 2026/08/06
在Gitcode上查看源码Set Account Interface
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This interface is used to set a user.
Privilege
UserMgnt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=68h |
| 5 | User ID |
| 6 | Operation 0: No password is set. 1: Set the user password. When the IPMI login interface is changed from disabled to enabled, the user password must be set. In other scenarios, the user password is optional. |
| 7 | bit0-Web: 0 disabled; 1 enabled bit1-SNMP: 0 disabled; 1 enabled bit2-IPMI: 0 disabled; 1 enabled bit3-SSH: 0 disabled; 1 enabled bit4-SFTP: 0 disabled; 1 enabled bit6-Local: 0 disabled; 1 enabled bit7-Redfish: 0 disabled; 1 enabled |
| 8 | Reserved. |
| 9 | Length: indicates the password length. |
| 10:N | Password data, containing a maximum of 20 characters. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Disable the user interface.
Request:
bash
ipmitool raw 0x30 0x93 0xDB 0x07 0x00 0x68 0x03 0x00 0x00 0x00 0x3 0x00 0x01 0x02Response:
text
db 07 00