代码仓
中
Get BMC Auxiliary Firmware Info
更新时间: 2026/08/06
在AtomGit上查看源码

Get BMC Auxiliary Firmware Info ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Obtains BMC auxiliary firmware information.

Privilege ​

ReadOnly

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 65h
5:6Reserved extended field. Set it to 0.

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Version, BMC Platform Verify. OEM by Huawei
[7:4]-Version.V
0-V1001-V2002-V3
[3:0]-Version.R
0-R0011-R002
6ECO-FT status
0: unsupport
1: support
This parameter is dedicated for 2288H V5. For other models, the value of ECO-FT status is 0.

Command Example ​

Obtain BMC auxiliary firmware information. ​

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 65 00 00" smi 0

Response:

text
0f 31 00 93 00 db 07 00 20 00

Back to Index ​