Function Description
Obtains BMC auxiliary firmware information.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 65h |
| 5:6 | Reserved extended field. Set it to 0. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Version, BMC Platform Verify. OEM by Huawei [7:4]-Version.V 0-V1001-V2002-V3 [3:0]-Version.R 0-R0011-R002 |
| 6 | ECO-FT status 0: unsupport 1: support This parameter is dedicated for 2288H V5. For other models, the value of ECO-FT status is 0. |
Command Example
Obtain BMC auxiliary firmware information.
Request:
ipmicmd -k "0f 00 30 93 db 07 00 65 00 00" smi 0Response:
0f 31 00 93 00 db 07 00 20 00