Set Hdd Power Status
更新时间: 2026/08/06
在Gitcode上查看源码

Set Hdd Power Status

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Sets the power status of a hard disk.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Subcommand, subcommand=63h
50: reserved, indicating that the disk location is not distinguished.
1: Front hard disk backplane
2: Rear hard disk backplane
6Reserved parameter. The value is 0.
7Number of a hard disk.
8Reserved parameter. The value is 0.
9Power status of the hard drive.
0: power-off
1: power-on
2: restores the default power-on or power-off status. (This status is not supported when Data[5] is set to 0.)

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the power status of a hard disk.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 63 00 00 00 00 01" smi 0

Response:

text
0f 31 00 93 d6

Back to Index