Get Hdd Power Status
更新时间: 2026/08/06
在Gitcode上查看源码

Get Hdd Power Status

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Shows the power status of hard disks.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=62h
50: The previous value is a reserved value. In this case, the hard disk location is not distinguished.
1: Front hard disk backplane
2: Rear hard disk backplane
6Reserved parameter. The value is 0.
7Number of a hard disk.
8Reserved parameter. The value is 0.

Response Information

Command Example

Query the power status of a hard disk.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 62 00 00 00 00" smi 0

Response:

text
0f 31 00 93 cb

Back to Index