代码仓
中
Get BMC Configuration
更新时间: 2026/08/06
在AtomGit上查看源码

Get BMC Configuration ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details
26.062026/05/09Added parameter: BMC boot status (0x4F)

Basic Information ​

Function Description ​

Obtaining BMC Parameters

Privilege ​

ReadOnly

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 5bh
5:6Parameter selector. For details, see Table 1. Low-order bytes are placed before low-order bytes.
7:8Data length. The least significant byte is placed before the least significant byte.
9:NParameter data. For details, see Table 1.

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:NData. For details, see Table 1.

Command Example ​

Obtain the cause of the BMC reset. ​

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 5b 0f 00" smi 0

Response:

text
0f 31 00 93 00 db 07 00 02

Back to Index ​