Get BMC Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Get BMC Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
| 26.06 | 2026/05/09 | Added parameter: BMC boot status (0x4F) |
Basic Information
Function Description
Obtaining BMC Parameters
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 5bh |
| 5:6 | Parameter selector. For details, see Table 1. Low-order bytes are placed before low-order bytes. |
| 7:8 | Data length. The least significant byte is placed before the least significant byte. |
| 9:N | Parameter data. For details, see Table 1. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:N | Data. For details, see Table 1. |
Command Example
Obtain the cause of the BMC reset.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 5b 0f 00" smi 0Response:
text
0f 31 00 93 00 db 07 00 02