Set BBU/Power Info
更新时间: 2026/08/06
在AtomGit上查看源码

Set BBU/Power Info ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Setting BBU information

Privilege ​

PowerMgnt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=56h
5ID:BBUID
6For details about the parameter selector, see Table 1.
7:8Writing Offset
The offset parameter can only be selected from the BBU pmbus command word. For details, see Table 2.
9Writing Length
The value varies with the writing offset. For details, see Table 2.
10:NData

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:NData

Command Example ​

Set a forcible alarm for a BBU. ​

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 56 00 01 cc 00 02 ff ff" smi 0

Response:

text
0f 31 00 93 00 db 07 00 00