Set BBU/Power Info
更新时间: 2026/08/06
在Gitcode上查看源码

Set BBU/Power Info

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Setting BBU information

Privilege

PowerMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=56h
5ID:BBUID
6For details about the parameter selector, see Table 1.
7:8Writing Offset
The offset parameter can only be selected from the BBU pmbus command word. For details, see Table 2.
9Writing Length
The value varies with the writing offset. For details, see Table 2.
10:NData

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:NData

Command Example

Set a forcible alarm for a BBU.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 56 00 01 cc 00 02 ff ff" smi 0

Response:

text
0f 31 00 93 00 db 07 00 00