代码仓
中
Get SmartCooling Customized Inlet Environmen Range info
更新时间: 2026/08/06
在AtomGit上查看源码

Get SmartCooling Customized Inlet Environmen Range info ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Obtains the temperature of the air intake vent.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=46h

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Querying the Number of Temperature Values: count
6:6+count-1Data, reading count temperature values
6+count : 6+2countData, corresponding fan speed percentage. The number of read fan speed values is count + 1.

Command Example ​

Obtain the air intake vent temperature. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN