Get SmartCooling Customized Inlet Environmen Range info
更新时间: 2026/08/06
在Gitcode上查看源码Get SmartCooling Customized Inlet Environmen Range info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the temperature of the air intake vent.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=46h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Querying the Number of Temperature Values: count |
| 6:6+count-1 | Data, reading count temperature values |
| 6+count : 6+2count | Data, corresponding fan speed percentage. The number of read fan speed values is count + 1. |
Command Example
Obtain the air intake vent temperature.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN