Set SmartCooling Customized Inlet Environmen Range info
更新时间: 2026/08/06
在Gitcode上查看源码Set SmartCooling Customized Inlet Environmen Range info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Configures the air intake vent temperature.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=45h |
| 5 | Count: specifies the number of temperature values to be written. |
| 6:6+count-1 | Data, count temperature values |
| 6+count: 6+2count | Data, corresponding to the fan speed percentage. The number of written fan speed values is count+1. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the temperature of the air intake vent.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN