Get Device Name
更新时间: 2026/08/06
在Gitcode上查看源码Get Device Name
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the device name.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 0x40h |
| 5 | Device Type Parameter For details, see Table 3. |
| 6 | type 0: indicates lighting identification. 2: indicates the root BDF number. 3: root BDF+port number 4: new indicator identification solution 5: indicates that the rootBDF number is used to obtain the chip type information. Others: reserved |
| 7 | Length Field Data Length |
| 8:N | Transfer parameters based on the recognition rule. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code 80h-Device not present |
| 2:04 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:N | 0-3: Data Silkscreen data that is actually returned type=4: Data The format is as follows: Total number of disks whose indicators are on: 1 + Number of returned silkscreens: 1 + len: 1, data: N + len: 1, data: N +... The value of type is 5: Data. Indicates the queried chip type. |
Command Example
Query the chip type.
Request:
bash
ipmitool raw 0x30 0x93 0xdb 0x07 0x00 0x40 0x4A 0x05 0x0C 0x30 0x30 0x30 0x30 0x3a 0x37 0x63 0x3a 0x30 0x30 0x2e 0x30Response:
text
db 07 00 43 50 55 20 49 6e 74 65 67 72 61 74 69 6f 6e