Set Access Rule Configuration
更新时间: 2026/08/06
在Gitcode上查看源码

Set Access Rule Configuration

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Configure login rules.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 2Eh
5Access rule parameter. For details, see Table 1.
6Block Selector (00h if parameter does not require a block number)
7[7:1]: reserved
[0]: cascading flag
0: last data
1: middle data
8Offset of the data to be written. The value starts from 0. If the data is long and needs to be written for multiple times, the data must be written from the beginning to the end in sequence.
9Length: length of the data to be written.
10:NWritten data

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Configure a login rule.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index