Set Power Supply Info Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Set Power Supply Info Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set power supply parameters.
Privilege
PowerMgnt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=2Dh |
| 5 | Power Supply Selector, 1 based |
| 6 | Power supply information parameter. For details, see Table 1. |
| 7 | [7:1]-reserved [0]: cascading flag 0: last data 1: middle data |
| 8 | Offset, indicating the offset of the written data. The value starts from 0. Write data in sequence when they are written as multiple frames. |
| 9 | Length: write length |
| 10:N | Written data |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set power supply parameters.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 2d 00 16 00 00 01 81" smi 0Response:
text
0f 31 00 93 00 db 07 00