Set Power Supply Info Configuration
更新时间: 2026/08/06
在Gitcode上查看源码

Set Power Supply Info Configuration

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Set power supply parameters.

Privilege

PowerMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=2Dh
5Power Supply Selector, 1 based
6Power supply information parameter. For details, see Table 1.
7[7:1]-reserved
[0]: cascading flag
0: last data
1: middle data
8Offset, indicating the offset of the written data. The value starts from 0.
Write data in sequence when they are written as multiple frames.
9Length: write length
10:NWritten data

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set power supply parameters.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 2d 00 16 00 00 01 81" smi 0

Response:

text
0f 31 00 93 00 db 07 00