Set Alert Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Set Alert Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This parameter is used to set alert reporting parameters.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=15h |
| 5 | Destination Selector The value ranges from 1 to 4. For a non-server configuration, set this parameter to 0xff. |
| 6 | Alert parameter. For details, see Table 1. |
| 7 | [7:1]: reserved [0]: cascading flag 0: last frame of data 1: middle data |
| 8 | Offset, indicating the offset of the written data. The value starts from 0. Write data in sequence when they are written as multiple frames. |
| 9 | Length: length of the data to be written. |
| 10:N | Data to write |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Obtain the highest event severity of sensor 0.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN